Uploaded image for project: 'VPMS Web Application'
  1. OVPMS-1856

System Message Print fails with long message

    Details

    • Type: Bug
    • Status: Resolved
    • Priority: Trivial
    • Resolution: Fixed
    • Affects Version/s: 1.9
    • Fix Version/s: 1.9.1
    • Component/s: Reporting
    • Labels:
      None
    • Sprint:

      Description

      Printing a long system message fails because in the System Message.jrxml the $F

      {message}

      field is in the page header and this cannot exceed the page size. Fix is to move it to the Detail section.
      Same fix applied to Message.jrxml and Audit Message.jrxml

        Attachments

          Activity

            People

            • Assignee:
              tanderson Tim Anderson
              Reporter:
              tgething Tim Gething (Inactive)
            • Votes:
              0 Vote for this issue
              Watchers:
              2 Start watching this issue

              Dates

              • Created:
                Updated:
                Resolved:

                Time Tracking

                Estimated:
                Original Estimate - Not Specified
                Not Specified
                Remaining:
                Remaining Estimate - 0h
                0h
                Logged:
                Time Spent - 0.75h
                0.75h